Patients on HeartMate 3 have fewer blood-related events than those on HeartMate II, according to a recent study.

A six-month analysis of the pivotal MOMENTUM 3 trial found that patients implanted with the new HeartMate 3 left ventricular assist system (LVAS) had fewer adverse clotting and bleeding events than patients implanted with the control, HeartMate II LVAS.

In this randomized, non-blinded study, a multi-institutional team found that 69 percent of the 151 patients who received Abbott's Heartmate 3 survived without any bleeding or clotting-related adverse events, compared to 55 percent of those who received the Heartmate II. Both devices are made by Abbott.

The researchers also devised a novel scoring system - the HemoCompatibility Score (HCS) - to quantify the burden of such events and their clinical relevance. Lower scores are better.

"For the HCS, mild events, such as two or fewer non-surgical bleeding episodes, receive one point," explained University of Chicago's Nir Uriel. "A non-disabling stroke is assessed at 2 points. An operation to replace the device gets 3 points. A disabling stroke gets 4 points."

Patients with the HeartMate 3 had fewer of these adverse events - 28 percent of patients versus 38 percent for those on HeartMate II. Those on HeartMate 3 tended to have bleeding events, which are less likely to be severe. Those on HeartMate II had both bleeding and clotting events. They spent more time in the hospital.

There were 14 deaths overall in the first 30 days on the pump. Five of those patients were on the HeartMate 3; nine were on the HeartMate II.

The HeartMate 3 consequently scored numerically better on the HCS, collecting only 101 points, compared to 137 points acquired by the smaller group on HeartMate II. Those in whom the HCS score was higher, however, were less healthy overall. They were older, and also less likely to take aspirin to prevent blood clots.

Two thirds of the patients on the HeartMate 3 had no adverse events for six months, compared to half of those on the HeartMate II.

Overall, "patients implanted with the HeartMate 3 gained a significant increase in freedom from adverse events, driven predominantly by a reduction in non-disabling strokes and complete absence of pump thrombosis, compared with the HeartMate II," said senior author Mandeep R. Mehra.

"No patients on the HeartMate 3 had pump-related clotting, requiring a pump reoperation," Mehra noted. "There was also no difference in disabling strokes, a typically devastating complication."

The Heartmate 3 has certain potential advantages because it was "designed to prevent thrombosis," Uriel explained. It was engineered to be less destructive to blood cells as they are swept through the pump and into the aorta. "It has a frictionless rotor, wide gaps for permissive blood flow and reduced shear stress," he said.

The results are published in the journal Circulation.

Disclaimer: No Business Standard Journalist was involved in creation of this content

*Subscribe to Business Standard digital and get complimentary access to The New York Times

Smart Quarterly

₹900

3 Months

₹300/Month

SAVE 25%

Smart Essential

₹2,700

1 Year

₹225/Month

SAVE 46%
*Complimentary New York Times access for the 2nd year will be given after 12 months

Super Saver

₹3,900

2 Years

₹162/Month

Subscribe

Renews automatically, cancel anytime

Here’s what’s included in our digital subscription plans

Exclusive premium stories online

  • Over 30 premium stories daily, handpicked by our editors

Complimentary Access to The New York Times

  • News, Games, Cooking, Audio, Wirecutter & The Athletic

Business Standard Epaper

  • Digital replica of our daily newspaper — with options to read, save, and share

Curated Newsletters

  • Insights on markets, finance, politics, tech, and more delivered to your inbox

Market Analysis & Investment Insights

  • In-depth market analysis & insights with access to The Smart Investor

Archives

  • Repository of articles and publications dating back to 1997

Ad-free Reading

  • Uninterrupted reading experience with no advertisements

Seamless Access Across All Devices

  • Access Business Standard across devices — mobile, tablet, or PC, via web or app

More From This Section

First Published: Apr 07 2017 | 5:20 AM IST

Next Story